Battery Charger Testing & Commissioning Service

Service Details

EngineerBari™ provides professional Battery Charger Testing & Commissioning Services for 48V DC and 110V DC battery charger systems, ensuring safe installation, proper configuration, and reliable operation of DC charging equipment.

Objective of Charger Testing & Commissioning

✅ Ensure correct installation and configuration of battery chargers

✅ Verify charger performance and voltage regulation

Confirm proper float and boost charging operation

Validate alarm, protection, and monitoring functions

Ensure compatibility between charger and battery system

Scope of work:

Visual Inspection & Installation Verification:

Charger installation and mounting verification

Cable termination and polarity confirmation

Earthing and grounding inspection

Cooling system and ventilation verification

✅ Nameplate and rating confirmation

Input & Output Electrical Testing:

✅ AC input voltage verification

DC output voltage measurement

Output current capability verification

Voltage regulation performance testing

Charger efficiency observation

Charging Mode Verification:

Float charging voltage verification

Boost charging voltage and current verification

Automatic transition between float and boost modes

Battery charging current monitoring

Rectifier Module Testing:

Individual rectifier module performance testing

Current sharing verification between modules

Redundant charger configuration verification (N+1 system)

Alarm & Protection Function Testing:

Over-voltage protection test

Under-voltage alarm verification

Charger failure alarm simulation

AC failure alarm verification

High temperature alarm test

Functional System Test:

Battery charging operation verification

Charger response under load condition

Battery discharging and recharge observation

System recovery after AC power failure

Applicable Charger Types:

✅ 48V DC Telecom Battery Chargers

110V DC Substation Battery Chargers

Documentation, including:

Battery Charger Testing & Commissioning Report

Charger Parameter Configuration Record

Alarm and Protection Test Results

Functional Test Summary

Commissioning Completion Certificate

Safety & Compliance:

Commissioning performed by qualified electrical engineers

Compliance with site safety and lock-out procedures

Proper isolation during testing activities

Risk assessment prior to commissioning work

Accommodation & Transportation

Accommodation and transportation for EngineerBari engineers shall be the following: Provided by the client OR

Charged separately and included in the service invoice (as mutually agreed prior to mobilization)

Why Choose EngineerBari™

Services delivered by verified professional engineers

Extensive experience in substation DC systems

Accurate testing using calibrated instruments

Professional commissioning reports accepted by utilities and EPC contractors

Reliable support for new installations and system upgrades

✅ Partial payment opportunity.

Estimated Service Fee : 20,000.00

Back to Services

Customer Reviews

4.8

★★★★★
Based on 124 reviews

You may also like

Physical
33kV Indoor XLPE Cable Termination Service
33kV Indoor XLPE Cable Termination Service
৳50000.00 5.0 (1)
View Details
Physical
132kV Indoor XLPE Cable Termination Service
132kV Indoor XLPE Cable Termination Service
৳50000.00 0.0 (0)
View Details
Physical
230kV Indoor XLPE Cable Termination Service
230kV Indoor XLPE Cable Termination Service
৳100000.00 0.0 (0)
View Details
Physical
33KV Outdoor XLPE Cable Termination Service
33KV Outdoor XLPE Cable Termination Service
৳50000.00 0.0 (0)
View Details

Need a Custom Service?

Didn’t find what you're looking for?
Call our expert team 24/7 at +8801789262512 ,
and we’ll help you with the right engineer.